Analysis of voltage drop causes at SMK Ponpes Manbaul Ulum Cirebon

Main Article Content

Lutfi Zulfiyan

Abstract

This study aimed to identify the causes, evaluate, and quantify the magnitude of voltage drop at SMK Ponpes Manba'ul’Ulum Cirebon. A descriptive quantitative approach using a single case study strategy was applied. Data were collected from PT PLN ULP Sumber, Cirebon, and through direct field measurements using a Digital Earth Tester, Digital Insulation Tester, and monitoring of a three-phase kWh meter. The findings revealed that the main cause of voltage drop was transformer overload at Distribution Substation CKPB, with a loading level of 91.20%, exceeding the 80% limit specified by the Indonesian Electricity Supply Standard (SPLN). Additional contributing factors included a 710-meter conductor length with a 70 mm² cross-sectional area, inter-phase load imbalance (I₁ = 105 A, I₂ = 149 A, I₃ = 141 A), and insulation resistance anomalies detected at several test points (0 MΩ at N-T, T-G, and N-G). Before transformer uprating, the voltage drop reached 28.49 V (14.92%), exceeding the SPLN 72:1987 tolerance range of 5–10%. After uprating the transformer capacity from 100 kVA to 160 kVA combined with load splitting, the voltage drop decreased to 13.57 V (6.33%) and transformer loading declined to 57.10%.

Article Details

How to Cite
Analysis of voltage drop causes at SMK Ponpes Manbaul Ulum Cirebon. (2026). Journal of Emerging Innovations in Engineering , 2(01), 31-42. https://doi.org/10.65664/jeie.v2i01.16
Section
Articles

How to Cite

Analysis of voltage drop causes at SMK Ponpes Manbaul Ulum Cirebon. (2026). Journal of Emerging Innovations in Engineering , 2(01), 31-42. https://doi.org/10.65664/jeie.v2i01.16

References

Adegoke, S. A., Sun, Y., Adegoke, A. S., & Ojeniyi, D. (2024). Optimal placement of distributed generation to minimize power loss and improve voltage stability. Heliyon, 10(21), e39298. https://doi.org/10.1016/j.heliyon.2024.e39298

Ardiansyah, M. R., Tharo, Z., & Erivianto, D. (2025). Analysis of drop voltage in low voltage network (JTR) 380/220 Volt distribution substation of PT PLN (Persero) ULP Tanah Jawa. International Conference of Digital Sciences and Engineering Technology, 469–480. https://proceeding.pancabudi.ac.id/index.php/ICDSET/article/view/448

Asmaul., Anwar, R. M., Hafid, A., & Faharuddin, A. (2024). Analisis drop tegangan pada gardu distribusi jaringan tegangan rendah (JTR) PT.PLN (PERSERO) ULP KAREBOSI. Arus Jurnal Sains dan Teknologi, 2(2). https://jurnal.ardenjaya.com/index.php/ajst/article/view/645

Aziza, N. (2023). Metodologi penelitian 1: Deskriptif kuantitatif. ResearchGate. https://www.researchgate.net/publication/371988490

Bachari, Y. E., Mohamad, Y., Yusuf, T. I., & Amali, L. M. K. (2024). Analysis of voltage drop and power losses on medium voltage 20 KV distribution system Kotamobagu area supplied from PLTD Kotamobagu. JEECS (Journal of Electrical Engineering and Computer Sciences), 9(1), 79–88. https://doi.org/10.54732/jeecs.v9i1.9

Costanzo, L., Vitelli, M., & Tarasiuk, T. (2021). A study of load imbalance influence on power quality assessment for distribution networks. Electronics, 2(1), 5. https://www.mdpi.com/2673-4826/2/1/5

Eftimie, S. A., et al. (2023). Distribution network topology planning and optimization: A brief review. E3S Web of Conferences, 393, 00054. https://doi.org/10.1051/e3sconf/202339300054

Elphick, S., Robinson, D., & Perera, S. (2024). Quantifying the economic impact of supply voltage magnitude on consumers. Energies, 17(22), 5590. https://doi.org/10.3390/en17225590

Freire, P. E., et al. (2025). Earthing in low-voltage systems: A documental research. Research, Society and Development, 14(11), e50005. https://doi.org/10.33448/rsd-v14i11.50005

Harrison, H., Birks, M., Franklin, R., & Mills, J. (2017). Case study research: Foundations and methodological orientations. Forum Qualitative Sozialforschung / Forum: Qualitative Social Research, 18(1), Art. 19. https://www.qualitative-research.net/index.php/fqs/article/view/2655

Ikhsan, M., Abrianto, H., & Gultom, A. (2025). Studi meminimalisir beban kapasitif sistem tenaga listrik. Innovative: Journal of Social Science Research, 5(1). https://j-innovative.org/index.php/Innovative/article/download/19343/13122/36495

Kim, C. H., Kim, H. J., & Kim, J. H. (2020). Analysis of thermal characteristics and insulation resistance based on the installation year and accelerated test by electrical socket outlets. PMC, 11(1), 1–14. https://pmc.ncbi.nlm.nih.gov/articles/PMC7728825/

La Elo, Y., Dali, R., Bura, M., & Tannur, O. (2023). Analisis ketidakseimbangan beban pada gardu distribusi tipe BBD kampung Tanama Fakfak. Jurnal Informasi Sains dan Teknologi, 6(2), 133–141. https://isaintek.polinef.ac.id/index.php/isaintek/article/download/148/143/618

Lu, Y., Gong, Y., Huang, C., Gu, S., Tong, J., & Huang, W. (2024). A low voltage load balancing distribution method considering street information and V2G technology application. Frontiers in Energy Research, 12, 1479216. https://doi.org/10.3389/fenrg.2024.1479216

Mbembati, H., & Bakiri, H. A. (2023). Transformer faults in Tanzanian electrical distribution networks: Indicators, types, and causes. Journal of Electrical Systems and Information Technology, 10, 34. https://doi.org/10.1186/s43067-023-00103-3

Medina, et al. (2022). Analisis jatuh tegangan jaringan distribusi 20 kV pada penyulang CPK PT. PLN (Persero) UP3 Bandung. Prosiding SNETO, 1(1), 609. https://eproceeding.itenas.ac.id/index.php/sneto/article/download/735/609/644

Mistry, A., & Shah, T. (2024). Grounding grid design: A review. Journal of Electrical Systems, 20(3), 2594–2601. https://journal.esrgroups.org/jes/article/download/4269/3126/7722

Nadia, et al. (2024). Voltage drop study on medium voltage network system. Fidelity: Jurnal Ilmiah Ketenagalistrikan, 3(2). https://fidelity.nusaputra.ac.id/article/view/261

Pardosi, E. S., & Nasution, M. H. (2024). Perbaikan jatuh tegangan dan rugi daya pada jaringan sambungan rumah. Jurnal Listrik, Instrumentasi, dan Elektronika Terapan (JULIET), 5(1). https://jurnal.ugm.ac.id/juliet/article/download/87020/38914

Prastia, R., et al. (2024). Analysis of voltage drop improvement using transformer insertion method in LG-02 receiver Lhokseumawe City. Applied Engineering, Innovation, and Technology, 1(1). https://www.researchgate.net/publication/381676149

Qurraisyn, A. Q., Latupeirissa, H., & Mbitu, E. T. (2023). Pengaruh panjang jaringan tegangan rendah terhadap susut teknis. Jurnal Teknik Industri Universitas Suryadarma, 10(2). https://journal.universitassuryadarma.ac.id/index.php/jti/article/download/1308/1264

Samuel, I. A., Toyin, D. A., Somefun, T. E., Awelewa, A. A., & Abba-Aliyu, S. (2024). Evaluation and improvement of power quality of distribution network: A case study of Covenant University, Ota. Frontiers in Energy Efficiency, 2, 1389622. https://doi.org/10.3389/fenef.2024.1389622

Sunaryo, & Faisal, M. (2022). Analisis penempatan transformator distribusi berdasarkan drop voltage pada PT. PLN (Persero) Distribusi Lamongan menggunakan Software ETAP 19.0. Jurnal Teknik Mesin, Elektro dan Ilmu Komputer, 3(1). https://ejurnal.politeknikpratama.ac.id/index.php/jtmei/article/download/2888/2712

Tahalele, T. J., & Yesaya, M. C. (2024). Analisis jaringan tegangan rendah (JTR) untuk memperbaiki jatuh tegangan gardu distribusi Passo. Jurnal Fisika Papua, 3(1), 8–10. https://doi.org/10.31957/jfp.v3i1.160

Tatarenko, A., et al. (2024). Performance optimization of grounding system for multi-voltage electrical installation. Applied Sciences, 15(15), 8600. https://doi.org/10.3390/app15158600

Turahma, A., Fadhillah, N., & Samsurizal, S. (2025). Simulation-based voltage drop mitigation in a 20 kV distribution network using conductor uprating base on ETAP 12.6. Journal of Sustainable Innovation Engineering, 1(1). https://sustainable.aks.or.id/index.php/sustainable/article/view/2

Wang, Z., et al. (2023). Energy consumption analysis of power grid distribution transformers based on an improved genetic algorithm. PeerJ Computer Science, 9, e1632. https://doi.org/10.7717/peerj-cs.1632

Wardoyo, S., Munarto, R., & Setiawan, B. (2025). Analisis pembebanan dan manajemen transformator distribusi. Surya Teknika, 12(2), 238–246. https://ejurnal.umri.ac.id/index.php/JST/article/download/10313/3941

Wicaksono, G. S., et al. (2023). Study of distribution transformer voltage drops in Feeder 5 outgoing districts 4 and 6 at PT PLN (Persero) Tarakan City, North Kalimantan. Journal of Emerging Supply Chain, Clean Energy, and Process Engineering, 2(1), 17–31. https://www.academia.edu/102599215

Yin, R. K. (2018). Case study research and applications: Design and methods (6th ed.). SAGE Publications. https://uk.sagepub.com/en-gb/eur/case-study-research-and-applications/book250150

Zhao, F., et al. (2023). Traceability analysis for low-voltage distribution network abnormal line loss using a data-driven power flow model. Frontiers in Energy Research, 11, 1272095. https://doi.org/10.3389/fenrg.2023.1272095