Analysis of gas pressure decline SF6 in 70kV circuit breaker bay transformer 3 at Babakan substation

Main Article Content

Arif Ramdhan Achmad
Muhammad Soleh
Sugeng Suprijadi

Abstract

This study analyzes the decrease in SF₆ gas pressure in the 70 kV circuit breaker Transformer Bay 3 at Babakan Substation, which affects the reliability of the power system. SF₆ gas is used as an insulating medium due to its high dielectric strength but is susceptible to micro-leakage, which degrades equipment performance. This research employs a qualitative approach with a case study strategy based on primary data obtained from field observations, interviews, and testing documentation before and after the replacement of the T-phase pole. Gas pressure monitoring was conducted using a FLIR Gas 306 camera and digital measuring instruments, with thematic analysis employed to identify causes and evaluate repair effectiveness. The results showed that a fine leak at the lower T-phase pole was the main cause of gas pressure reduction. After pole replacement, the rate of pressure drop decreased from 0.00459 MPa/day to 0.00016 MPa/day, indicating a 35.3% increase in insulation effectiveness and a 64.6% reduction in leakage rate. Operational feasibility tests met the SPLN 52-1:1983 standard, confirming that the circuit breaker is suitable for operation. I while applying condition-based maintenance (CBM) and infrared detection proved efficient in identifying SF₆ leakage and supporting predictive maintenance practices at substations.

Article Details

Section
Articles

References

Braun, V., & Clarke, V. (2006). Using thematic analysis in psychology. Qualitative Research in Psychology, 3(2), 77–101. https://doi.org/10.1191/1478088706qp063oa

Freire, W. P., Melo, W. S., Do Nascimento, V. D., Nascimento, P. R. M., & de Sá, A. O. (2022). Towards a Secure and Scalable Maritime Monitoring System Using Blockchain and Low-Cost IoT Technology. Sensors, 22(13). https://doi.org/10.3390/s22134895

Fuhai, L., Zhan, T., Yeyuan, L., & Yongqiang, D. (2019). Analysis of the Causes of Gas Leakage of a 500kV SF6 Circuit Breaker. IOP Conference Series: Earth and Environmental Science, 310. https://doi.org/10.1088/1755-1315/310/3/032009

Hodencq, S., Brugeron, M., Fitó, J., Morriet, L., Delinchant, B., & Wurtz, F. (2021). OMEGAlpes, an open-source optimisation model generation tool to support energy stakeholders at district scale. Energies, 14(18). https://doi.org/10.3390/en14185928

James, G. (2017). Cul-de-sacs and narrative data analysis – A less than straightforward journey. Qualitative Report, 22(12), 3102–3117. https://doi.org/10.46743/2160-3715/2017.3163

Jian-Bo, H. (2010). Application of Gas Find IR-LW in Condition-based Maintenance of SF_6 Electrical Equipment. High Voltage Apparatus. https://consensus.app/papers/application-of-gas-find-irlw-in-conditionbased-jian-bo/72d92b1b072557968b0cb0eb3e6d933c/

Kud, K., Woźniak, M., & Badora, A. (2021a). Impact of the energy sector on the quality of the environment in the opinion of energy consumers from southeastern poland. Energies, 14(17). https://doi.org/10.3390/en14175551

Kud, K., Woźniak, M., & Badora, A. (2021b). Impact of the energy sector on the quality of the environment in the opinion of energy consumers from southeastern poland. Energies, 14(17). https://doi.org/10.3390/en14175551

Liang, J., & Hou, J. (2019a). Simulation of 5G Secondary Synchronization Signal Detection. 2019 International Conference on Intelligent Computing, Automation and Systems (ICICAS), 607–612. https://doi.org/10.1109/ICICAS48597.2019.00133

Liang, J., & Hou, J. (2019b). Simulation of 5G Secondary Synchronization Signal Detection. 2019 International Conference on Intelligent Computing, Automation and Systems (ICICAS), 607–612. https://doi.org/10.1109/ICICAS48597.2019.00133

Lindskog, A., Neandhers, K., & Thiringer, T. (2024). Early SF6 Gas Leakage Detection Through a Novel Comparison Algorithm Based on Pressure Only. IEEE Transactions on Power Delivery, 39, 922–930. https://doi.org/10.1109/tpwrd.2023.3340514

Liu, B., Gao, F., & Li, Y. (2023). Cost-Sensitive YOLOv5 for Detecting Surface Defects of Industrial Products. Sensors, 23(5). https://doi.org/10.3390/s23052610

Naveen, B., Verma, R., & Dahiya, S. (2013). CDM in Sub-Stations by Replacement of SF 6 Gas in Circuit. https://consensus.app/papers/cdm-in-substations-by-replacement-of-sf-6-gas-in-circuit-naveen-verma/73923e9374c95c75bfceba2975d4983d/

Ober, J., Karwot, J., & Rusakov, S. (2022). Tap Water Quality and Habits of Its Use: A Comparative Analysis in Poland and Ukraine. Energies, 15(3). https://doi.org/10.3390/en15030981

Ogiboski, L., Filho, J., Cunha, A., Kajikawa, C., Magrini, L., & Jardini, J. (2011). Real time system to monitor SF6 leakage and quality of gas in a gas insulated substation. 2011 IEEE Trondheim PowerTech, 1–6. https://doi.org/10.1109/ptc.2011.6019181

Park. (2020). Efficient Multimedia Sensing and Computing for Smart City. 2020 IEEE 18th International Conference on Industrial Informatics (INDIN), 1, 707–708. https://doi.org/10.1109/INDIN45582.2020.9442345

Rahman, S., Saha, S., Haque, M. E., Islam, S. N., Arif, M. T., Mosadeghy, M., & Oo, A. M. T. (2022). A framework to assess voltage stability of power grids with high penetration of solar PV systems. International Journal of Electrical Power & Energy Systems, 139, 107815. https://doi.org/https://doi.org/10.1016/j.ijepes.2021.107815

Riad, K. (2023). Token-Revocation Access Control to Cloud-Hosted Energy Optimization Utility for Environmental Sustainability. Applied Sciences (Switzerland), 13(5). https://doi.org/10.3390/app13053142

Saravanan, A., Elghaffar, A., Ali, Y. S., & Mohamed, A. (2015). The Optimum Tests for High Voltage SF6 Circuit Breaker In The New Substation Before Energize With The National Grid. International Journal of Technology Enhancements and Emerging Engineering Research, 3, 52–57. https://consensus.app/papers/the-optimum-tests-for-high-voltage-sf6-circuit-breaker-in-saravanan-elghaffar/e0c4c0d48a755753a53a491ef73e8c69/

Vianna, E., Abaide, A., Canha, L., & Miranda, V. (2017). Substations SF6 circuit breakers: Reliability evaluation based on equipment condition. Electric Power Systems Research, 142, 36–46. https://doi.org/10.1016/j.epsr.2016.08.018

Wang, C., Hu, J., Yang, K., & Mei, H. (2021a). Energy-awareness caching strategy in D2D communication networks. 2021 IEEE International Conference on Smart Internet of Things (SmartIoT), 46–51. https://doi.org/10.1109/SmartIoT52359.2021.00017

Wang, C., Hu, J., Yang, K., & Mei, H. (2021b). Energy-awareness caching strategy in D2D communication networks. 2021 IEEE International Conference on Smart Internet of Things (SmartIoT), 46–51. https://doi.org/10.1109/SmartIoT52359.2021.00017

Yu-Guo, B. (2011). SF_6 Circuit Breaker and the Gas Management. Electric Switchgear. https://consensus.app/papers/sf6-circuit-breaker-and-the-gas-management-yu-guo/b49f61bdaa83541dbb99aa06fc8de564/

Zamani, Z., Kejani, M. T., Khalkhali, S. H., & Razi-Kazemi, A. (2024). Assessing Circuit Breaker Gas Pressure Using Temperature Analysis. 2024 14th Smart Grid Conference (SGC), 1–6. https://doi.org/10.1109/sgc64640.2024.10983718

Zhai, J., Zhang, X., Zhao, S., & Zou, Y. (2023). Modeling and Experiments of a Wireless Power Transfer System Considering Scenarios from In-Wheel-Motor Applications. Energies, 16(2). https://doi.org/10.3390/en16020739

Zhang, Y., Zhou, J., & Lin, W. (2021a). Knowledge Graph-Based Sequence Recommendation. 2021 8th International Conference on Computational Science/Intelligence and Applied Informatics (CSII), 12–17. https://doi.org/10.1109/CSII54342.2021.00010

Zhu, C., Shi, W., Chen, Z., Xiao, N., & Lu, Y. (2020a). An Efficient Approach to Vectorize the Hybrid Breadth-First Search. 2020 IEEE 22nd International Conference on High Performance Computing and Communications; IEEE 18th International Conference on Smart City; IEEE 6th International Conference on Data Science and Systems (HPCC/SmartCity/DSS), 532–537. https://doi.org/10.1109/HPCC-SmartCity-DSS50907.2020.00066